Operating and Installation
Instructions
Downdraft Ventilation System
DA 6480, DA 6490
DAG 500, DAG 1000
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 09 045 140
en - US, CA
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - DAG 500, DAG 1000

Operating and InstallationInstructionsDowndraft Ventilation SystemDA 6480, DA 6490DAG 500, DAG 1000To prevent accidentsand appliance damage,read these

Page 2 - Contents

Raising the vent / Turning onthe fan^Press the On/Off button on the top ofthe ventilation system.The vent will rise.The fan will start at power level

Page 3

Temperature warning §The ventilation system can becomevery hot during operation. It cancause burns, particularly whencooking with gas.The ventilation

Page 4 - COOKTOP GREASE FIRE:

Before cleaning or servicing theventilation system, disconnect itfrom the power supply, see"Important Safety Instructions".Cleaning the casi

Page 5

Special instructions for controlbuttonsThe controls may change or becomediscolored if not cleaned regularly,clean soiled areas immediately.Do not use

Page 6

Cleaning the grease filters^By hand: use a scrub brush with asolution of warm water and mild dishsoap.Do not use the pure detergent,aggressive all pur

Page 7 - Functional description

RepairsIn the event of a fault which you cannoteasily fix yourself, please contact theMiele Technical Service Department.^When contacting the Technica

Page 9

Installation InstructionsRead these instructions and the "Important Safety Instructions" before installingthis ventilation system.The instal

Page 11

Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an

Page 12 - Cleaning and Care

IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Functional description . . . . . . . . . . . . . . . .

Page 13

Appliance dimensions20

Page 14

a DAG 500 Internal blowerThe blower box can be mounted insuch a way that the vent collar isaligned to the left, the right, downwardsor towards the rea

Page 15 - After Sales Service

Cabinet dimensionsAppliance dimensions22

Page 16

Exhaust air ducting using the DAG 500internal blower, installed on the front ofthe appliance [vent duct 6" C(150 mm)]: a to the left or right, bd

Page 17 - Installation Instructions

Installation using the DAG 500 internal blowerDAG 500 mounted in front of theexhaust system.DAG 500 mounted behind the exhaustsystem.Note that the blo

Page 18

Installation using the DAG 1000 external blower connection plateExhaust air ducting to the front. Exhaust air ducting to the rear.Note that the back m

Page 19 - Caring for the environment

The ventilation system is installeddirectly behind the cooktop.For easiest installation, install theventilation system first, then thecooktop.The vent

Page 20 - Appliance dimensions

^ With the assistance of anotherperson, lift the appliance into theprepared cutout. The top mountingbrackets should rest on thecountertop.^Secure the

Page 21

^Remove the screws from thecountertop.^Lift the appliance back out of thecabinet.^Pre-drill the marked mounting holeson the cabinet floor.^Tighten the

Page 22

Venting direction towards the rear:In this case, the DAG 500 blower boxmust be modified.^Loosen the two screws holding theblower in the box.^ Take the

Page 23

READ AND SAVE THESEINSTRUCTIONSKeep these operating instructions ina safe place and pass them on to anyfuture user.Read these Instructions carefullybe

Page 24

^Plug the connection cable from theventilation system into the blowermotor.^ Remove the vent collar of the blowerbox.^Close the opening in the blower

Page 25

Installing the DAG 500 blower boxon the rearThe blower box can also be installed onthe back of the ventilation system:^ Remove the large cover on the

Page 26 - Installation

Preparing the electrical connection^Remove the cover of the terminalbox.^ Decide whether you would like thepower cable to enter the ventilationsystem

Page 27

^Connect the appliance to the electricpower supply.Observe the "Important safetyinstructions" and "Electricalconnection" warnings.

Page 28

Installation with the DAG 1000external blowerIf using DAG 1000 external blower, aconnection plate much be installed onthe ventilation system instead o

Page 29

,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and topr

Page 30

Never connect a ventilation systemto an active chimney, dryer vent,flue, or room venting ductwork. Seekprofessional advice beforeconnecting the ventil

Page 31

,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:All electrical work should beperformed by a qualified ele

Page 32

Electrical connection if using anexternal blowerIf using the external blower, install aconnection cable between theventilation system and the external

Page 34

~d) Before connecting the applianceto the power supply make sure that thevoltage and frequency listed on thedata plate correspond with thehousehold el

Page 35 - Air extraction

Alteration rights reserved / 4011INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOSTCURRENT PRODUCT SPECIFICATIONS, TECHN

Page 36

,WARNINGTO REDUCE THE RISK OFINJURY TO PERSONS IN THEEVENT OF A COOKTOPGREASE FIRE, OBSERVE THEFOLLOWING*:~a) SMOTHER FLAMES with a closefitting lid,

Page 37 - Electrical connection

Installation,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:~a) Installation work and electricalwiring mu

Page 38

The ventilation system offers two installation options:with the internal DAG 500exhaust blower(not included)The air is drawn through and cleanedby the

Page 39

Description of the appliance8

Page 40 - M.-Nr. 09 045 140 / 02

a On/Off button for the retractablevent and fanb Control panelc Retractable ventd Grease filtere Exhaust blower DAG 500(not included)The exhaust blowe