All electrical work should be carried
out by a suitably qualified and
competent person in strict
accordance with current local and
national safety regulations (BS 7671
in the UK).
This appliance can be connected to the
mains electricity supply either via a
plug and switched socket or via a
suitable fused spur connection unit.
The socket and on-off switch should be
easily accessible after the appliance
has been built in.
Connection to a fused spur connection
unit must be carried out by a suitable
qualified electrician only.
If the connection socket is not
accessible after installation (depending
on country) an additional means of
disconnection must be provided for all
poles. When switched off there must be
an all-pole contact gap of 3 mm in the
switch (including switch, fuses and
relays).
See data plate for connection details.
Ensure that these match the mains
supply.
Ensure power is not supplied to the
appliance until after installation work
has been carried out.
The appliance must only be
operated when built-in. This is to
ensure that all electrical parts are
shielded. Live parts must not be
exposed.
Do not connect the appliance to the
mains electricity supply via an
extension lead. These do not
guarantee the required safety of the
appliance.
Total connected load
See data plate
Voltage and fuse rating
AC230V/50Hz
Fuse rating 10 A
Release Type B or C
Residual current device
For extra safety it is advisable to install
a suitable residual current device with a
trip current of 30 mA.
Electrical connection
5