,
Connection to the gas supply, or conversion from one
type of gas to another, should only be undertaken by an
approved and registered gas installer in strict accordance
with local and national safety and building regulations.
When converting to a different type of gas, all burner jets
have to be changed.
Jet table
Burners Main jet(s) Ø Small jet(s) Ø
NG
Small burner
Medium burner
Large burner
Wok
0.90
1.10
1.43
2x 1.27 / 0.90
0.52
0.52
0.60
0.44
ULPG
Small burner
Medium burner
Large burner
Wok
0.52
0.66
0.81
2x 0.70 / 0.46
0.23
0.36
0.44
0.25
The jet markings refer to 1/100 mm of the jet diameter.
Conversion to another type of gas
49
Commentaires sur ces manuels