Miele DA 217-2 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Ventilateurs Miele DA 217-2. Miele DA 217-2 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Operating and installation instructions
Cooker hoods
DA 216-2, DA 216-2 EXT
DA 217-2
DA 219-2, DA 219-2 EXT
It is essential to read these
operating instructions before
GiWOZ
installing or using the machine,
to avoid the risk of accidents
or damage to the machine. M.-Nr. 05 609 490
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - DA 219-2, DA 219-2 EXT

Operating and installation instructionsCooker hoodsDA 216-2, DA 216-2 EXTDA 217-2DA 219-2, DA 219-2 EXTIt is essential to read theseoperating instruct

Page 2 - Contents

Functional descriptionThe cooker hood works with. . . air extractionThe air is drawn in and cleaned by thegrease filters and directed outside.The cook

Page 3 - Caring for the environment

OperationMain switchSwitch the main switch to "I". The fanand the lighting can now be operated. If the appliance is not going to be usedfor

Page 4 - Technical safety

To switch the fan offPress the On/Off touch control toswitch the fan off.The indicator lamp above the controlgoes out.Switching the lighting onThe hob

Page 5

Filter operating hours counterThe number of hours the appliance hasbeen in operation for is stored in mem-ory.The indicator lamp above the grease fil-

Page 6

Altering the filter operating hourscounterThe operating hours counter for thegrease filters is set to 30 hours. Thiscan be lengthened or shortened to

Page 7

Setting/altering the active charcoalfilter operating hours counterThe active charcoal filters are onlyused for cooker hoods which are setup for recirc

Page 8 - Description of the appliance

Cleaning and careBefore any cleaning or maintenancework the cooker hood must be dis-connected from the mains supply.Ensure that:– it is switched off a

Page 9

Grease filtersRe-usable metal filters are fitted whichremove solid particles (oil, dust, etc.)from the kitchen vapours, preventingsoiling of the cooke

Page 10 - Functional description

Fitting / replacing the activecharcoal filtersIf the cooker hood is connected for re-circulation, two active charcoal filtersmust be inserted in addit

Page 11 - Operation

Changing a light tubeDisconnect the cooker hood fromthe mains supply. Ensure that:– it is switched off at the wall socketand the plug has been withdra

Page 12

ContentsCaring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Warning and Safety instructio

Page 13

Appliance dimensionsAppliance dimensions20

Page 14

Safety regulations prohibit the fittingof this cooker hood over a solid fuelstove.For safety reasons a minimum safedistance must be maintained be-twee

Page 15

InstallationAssembly partsInstallation22

Page 16 - Cleaning and care

b 2 recirculation grilles(for recirculation mode only) c 2 protective sheets for use when fitting the tower.d 1 protective sheet for use when fitti

Page 17

Retaining platesThere are three retaining plates A, Band C for fixing the cooker hood to thewall. First of all drill the holes for attachingthe canopy

Page 18

Lightly secure retaining plate A intoposition using 5 x 40 mm screwsthrough the two holes and use thenotches to align with the middle line.Drill 4 mor

Page 19

At a maximum distance of 365 mmfrom the ceiling, hold retaining plateC against the wall and use the not-ches to align it with the middle line.Mark the

Page 20 - Appliance dimensions

Motor unit(not when operating the external fan)with air extractionIf a non-return flap is not present inthe venting system, the non-returnflap supplie

Page 21

Control unit(only when operating with an externalfan)Fit the exhaust socket supplied into thecanopy. It has an integrated non-returnflap. If a 150 mm

Page 22 - Installation

For appliances connected to an ex-ternal fan, model designation...EXT: Connect the control unit and the ex-ternal fan with the connection cableand the

Page 23

Caring for the environmentDisposal of packing materialThe transport and protective packinghas been selected from materialswhich are environmentally fr

Page 24

RecirculationIf site conditions are not suitable for thecooker hood to be used for air extrac-tion the appliance must be connectedfor recirculation.Pu

Page 25

Before fitting the extension pieceremove the protective foil.Bend the top hanging retainers ap-prox. 45° inwards. This makes fittingeasier.Recirculati

Page 26

The paper protective sheet protects theextension piece from being scratchedwhen the tower is being fitted. It isremoved when fitting is complete.Fold

Page 27

Hold the main tower gently apart andfit it over the extension piece.Then slide the tower down approx.2 cm into the canopy.Adjust the tower.Remove the

Page 28

Connection for air extractionDanger of toxic fumes.Please heed the "Warning andSafety instructions" to avoid thedanger of toxic fumes.The co

Page 29

Important:If the exhaust ducting is to run throughrooms, ceiling space etc. where theremay be great variations in temperaturebetween the different are

Page 30

Electrical connection All electrical work should be under-taken by a suitably qualified andcompetent person in strict accord-ance with national and lo

Page 31

Important The wires in the mains lead are col-oured in accordance with the followingcode:Green/yellow = earthBlue = neutralBrown = liveIf the applianc

Page 32

After Sales ServiceIn the event of a fault which you cannotcorrect yourself please contact:– Your Miele Dealeror– The Miele Service Department (see ba

Page 33

Technical data Rated loadDA 216-2, 217-2, 219-2 . . . . . . . 222 WLighting . . . . . . . . . . . . . . . . . 2 x 11 WVoltageUK, IRL, NZ . . . . . .

Page 34 - Connection for air extraction

Warning and Safety instructionsThis appliance conforms to currentsafety requirements. Incorrect usecan lead to injury and damage tothe appliance.Befor

Page 35

Alteration rights reserved / 44 / 000 GB / IRL / AUS / NZ / ZA – 1301This paper consists of cellulose which has been bleached without the use of chlor

Page 36 - Electrical connection

The appliance is only completelyisolated from the electricity supplywhen:– it is switched off at the wall socketand the plug removed. (Do not pullon t

Page 37

InstallationThe distance between the top ofthe cooker/hob and the bottom ofthe cooker hood must measure at least:– 450 mm above electric hobs andcooke

Page 38 - After Sales Service

When using the cooker hood inextraction mode at the same timeas another heating appliance which de-pends on the air in the room, (e.g. gas,oil or coal

Page 39 - Technical data

Description of the applianceDescription of the appliance8

Page 40

b Extension piecec Towerd Canopye Control panelf Main switchg Recirculation grillesh Hob lighting iGrease filtersjTouch control for the hob lighting

Commentaires sur ces manuels

Pas de commentaire