Miele F 1801 SF Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Non Miele F 1801 SF. Miele F 1801 SF Installation manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Operating and Installation
Instructions
Fridge-Freezer Combination
KF 1801 SF
KF 1811 SF
KF 1901 SF
KF 1911 SF
To prevent accidents
and appliance damage
read these instructions
before
installation or use.
M.-Nr. 09 169 650
en - US, CA
Vue de la page 0
1 2 3 4 5 6 ... 28 29

Résumé du contenu

Page 1

Operating and InstallationInstructionsFridge-Freezer CombinationKF 1801 SFKF 1811 SFKF 1901 SFKF 1911 SFTo prevent accidentsand appliance damageread t

Page 2 - Installation instructions

Niche dimensionsABKF 1801 SF, KF 1811 SF 30 ½" (774.6 mm) 30" (762 mm)KF 1901 SF, KF 1911 SF 36 ½" (927 mm) 36" (915 mm)Dimensions

Page 3 - Caring for the environment

Power supply and water connection1. Power supply2. Water connectionAKF 18X1 SF 15" (381 mm)KF 19X1 SF 18" (458 mm)Dimensions58

Page 4 - Installation

Before you beginRead these instructions completelyand carefully.Have the appliance installed by aqualified technician, according tothe enclosed instal

Page 5

Aligning the housing unitThe housing unit must be carefullyaligned using a spirit level beforeinstalling the appliance. The unitcorners must be at rig

Page 6

There are transportation safetydevices inside the appliance toprotect the shelves and storagecompartments until installation iscomplete. Do not remove

Page 7

^Remove the cover b.^Push the module into the slot until itlocks into place.^Connect the appliance to the powersupply and turn it on. After severalsec

Page 8

Mounting AccessoriesThe mounting accessories needed forinstalling the appliance into the nicheare included in the packaging. Severalplastic bags are i

Page 9

^Drill pilot holes:–1/8"(3mm)for5x60mmwoodscrews–1/16"(2mm)for4x15mmwoodscrews.^ Tightly secure the anti-tip brackets inthe niche.Be certain

Page 10 - Dimensions

Securing an alternative anti-tipdeviceIf the anti-tip brackets cannot beattached securely, an alternativeanti-tip device can be used.Ensure that there

Page 11

Sliding the appliance into theinstallation nicheIf a side-by-side installation isdesired, connect the two appliancestogether. See the Installation Man

Page 12 - Installing the appliance

Installation instructionsInformation is subject to change. Please refer to our website to obtain the mostcurrent product specification, technical &

Page 13

^To prevent the power cord frombecoming caught:Tie a piece of string to the middle ofthe power cord and feed it forwardunder the appliance. When slidi

Page 14

Aligning the appliance^Align the appliance with the customfront.The height-adjustable feet at the frontand rear can all be adjusted from thefront:– Fr

Page 15

Attaching the appliance to theinstallation niche^Open the appliance doors.^ Fasten the appliance on the left andright hand sides with the 3 (supplied)

Page 16

Attaching the toe-kick coverThe maximum height of the toe-kickcover is 4" (101 mm) from the top ofthe floor. Do not cover the ventilationslits in

Page 17

Mounting the air separatorThe air separator keeps the supply andexhaust air separate. This preventswarm exhaust air from flowing into themachine, opti

Page 18

All plumbing work should be carriedout by a suitably qualified andcompetent person, in accordancewith all applicable local and nationalregulations.The

Page 19

Preparing the water connectionThe connection to the householdwater supply must be installedbefore the appliance is installed.^Turn off the main water

Page 20

Connecting the water supplyWhen connecting the water pipe tothe solenoid valve of the appliance,follow the instructions supplied bythe manufacturer of

Page 21

,Avoid the risk of electricalshock- Plug into a grounded 3-prongoutlet.- Do not move the ground plug.- Do not use an adapter.- Do not use an extension

Page 22

Alteration rights reserved / 5011INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOSTCURRENT PRODUCT SPECIFICATIONS, TECHN

Page 23

Disposal of packing materialsThe cardboard box and packingmaterials are biodegradable andrecyclable. Please recycle.Ensure that any plastic wrappings,

Page 24

Have the appliance installed by aqualified technician, according tothe enclosed installation instructions.,WARNINGThis appliance is top-heavy andmust

Page 25 - Plumbing

BaseA fully loaded appliance is very heavy.The load-bearing capacity of your floormust meet the following requirements:KF 18X1 SF ...1,007 lbs (45

Page 26

Stainless steel panelsStainless steel door panels and toe-kickcovers are available from Miele.Installation optionsThere are many different installatio

Page 27

Installation with partition using the"Merging Kit"The minimum thickness of the partitionis5/8" (16 mm).If there is a partition with a t

Page 28 - Electrical connection

Adjusting the door openingangle (optional accessory)Depending on the installation site, itmay be necessary to adjust the dooropening angle to 90°.^Ope

Page 29 - M.-Nr. 09 169 650 / 01

Door dimensions (opening angle 90°)AKF 18X1 SF 325/8" (829 mm)KF 19X1 SF 3811/16" (982 mm)Door dimensions (opening angle 115°)ABKF 18X1 SF 3