Miele GAS COMBISET CS 1011 Instructions d'exploitation Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
When installing two or more appliances next to each other a spacer bar b must
be used between each one.
See "Fitting the spacer bars and support brackets".
Worktop cut-out
- two appliances
When installing two appliances, the
width of the cut-out required D is
calculated by adding dimensions A and
C.
Worktop cut-out
- three appliances
When installing three appliances the
width of the cut-out required (D) is
calculated by adding dimensions A, B
and C.
A = appliance width (288 mm or 380 mm or 576 mm) less 8 mm
B = appliance width (288 mm or 380 mm or 576 mm)
C = appliance width (288 mm or 380 mm or 576 mm) less 8 mm
D = width of worktop cut-out
When installing more than three
appliances for each additional
appliance add the relevant appliance
width (288 mm or 380 mm or
576 mm) to dimensions A, B and C.
Installation of several appliances
32
C
D
A
500
b
C
D
A
B
500
b
Vue de la page 31