To eliminate the risk of burns or fire
by reaching over heated surfaces
cabinet storage space above the
cooktop should be avoided. If cabinet
storage is necessary, the risk can be
reduced by installing a venting hood to
project horizontally a minimum of 5"
beyond the bottom of the cabinets.
~
Because of the heat radiated it is not
recommended to install the cooktop
above a drawer. It should be installed
above a cabinet base unit with a
dummy drawer front.
~
This appliance has not been
designed for maritime use or for use in
mobile installations such as recreational
vehicles or aircraft. However, under
certain conditions it may be possible
for installation in these applications.
Please contact the Miele Technical
Service Department with specific
requirements.
~
The cooktop must not be
permanently sealed into the countertop
when installed. The sealing strip under
the edge of the cooktop provides a
sufficient seal for the countertop. See
"Sealing".
Safety distances above the
appliance
The minimum safety distance given by
the hood manufacturer must be
maintained between the cooktop and
the hood above it. See the installation
instructions of the hood for these safety
measurements.
If the hood manufacturers instructions
are not available or if flammable objects
are installed over the cooktop (e.g.
cabinets, utensil rail, etc.), a minimum
safety distance of 30" (760 mm) must
be maintained.
If there is more than one appliance
beneath a hood, e.g. wok burner
and electric cooktop, and they have
different minimum safety distances
always select the greater distance.
IMPORTANT SAFETY INSTRUCTIONS