All electrical work should be by a
qualified electrician in accordance
with local and national codes.
To reduce the risk of electric shock,
disconnect the power supply by trip
-
ping the circuit breaker or removing
the fuse to the unit before perform
-
ing the installation or service.
^
Note to the installer:
Please leave these instructions with
the consumer.
Power supply:
Please check the data plate.
KM 421:
240 VAC, 60 Hz, 30 A fuse rating,
208 VAC, 60 Hz, 30 A fuse rating.
KM 424:
240 VAC, 60 Hz, 40 A fuse rating,
208 VAC, 60 Hz, 40 A fuse rating.
KM 427:
240 VAC, 60 Hz, 50 A fuse rating,
208 VAC, 60 Hz, 50 A fuse rating.
Make sure your electrical supply
matches the data plate.
Important
The appliance is provided with 3 leads;
L1 (black), L2 (red) and GND (green).
They must be connected to a dedi
-
cated line through the use of an ap
-
proved junction box.
For further information, see the wiring
diagram provided with the appliance.
WARNING:
THIS APPLIANCE MUST BE
GROUNDED!
Electrical connection
21