4 Touch current measurement
x
Note
On machines with an earth connection, touch current leakage measurements
should be carried out on all accessible conductive parts that are not connected
to the earth.
Warning!
Touch current measurement should only be carried out after the earth
connection of the unit under test has been checked and found to be satisfactory!
Dangerous voltages may exist on defective machines as well as on accessible
conductive parts that are not connected to earth!
Note
Touch current measurement should be carried out on the following accessible
conductive parts:
None.
Descriptive Technical Documentation
A-4 DTD no. 521-7135
This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.2005, DE_en