Miele H 370 Informations techniques Page 59

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 102
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 58
Novotronic Models
Technical Information
59
6.2.6 Fault Code F13
Cause:
The door-locking device (Pyrolitic) does not close because its drive is
defective
Remedy:
Replace locking device
Cause:
The door-locking device (Pyrolitic) does not close because the door cable
is defective
Remedy:
Replace the door lock cable
Cause:
The door-locking device (Pyrolitic) does not close because the door
temperature regulator is defective
Remedy:
Replace the door temperature regulator
6.2.7 Fault Code F14
Cause:
The door-locking device (Pyrolitic) does not close because its drive is
defective
Remedy:
Perform door lock manual override
Replace locking device
Cause:
The door-locking device (Pyrolitic) does not close because the door cable
is defective
Remedy:
Perform door lock manual override
Replace the door lock cable
Continued on next page.