6.3.27 Regulator Parameter
Initial Requirements
Turn the selector switch to “O”
Accessing
1. Open the door fully
2. Turn the selector to “Defrost”
3. Press the “Cook” or “Timer” button depending on the model 3 times
within 2 seconds
Acknowledgement Indicator
The display shows --00
Options
Note:
The service mode will be cancelled automatically after 5 minutes
or there is a power loss of more then 1 second
1. Wait approximately 10 seconds (optical interface check)
2. Press the “-“ or “+” button as appropriate to advance to service mode
position 32
3. The display shows the regulator parameter, e.g. P01
Note:
The regulator parameter can only be modified via service mode 31
Save and Quit
Press and hold the “Cook” or “Time” button for more then 3seconds